

Select high (2nd stage) gas heat rise airflow adjustmentĪirflow demand for second stage gas heat. On your LOCKPICK AIR control box are switch settings which allow you to program your Lockpick for the vehicle and application where it will be installed. Two dipswitches (S3-15, S3-16) shall be used to High Gas Heat Rise (Airflow) Adjustment S3. OFF OFF Nominal Value Specified on Rating Will vary based on conditions and technician Selections are set to approximate a specified temperature Each selection will use a differentĪirflow demand for first stage gas heat. Select low (1st stage) gas heat rise airflow adjustment Two dipswitches (S3-13, S3-14) shall be used to More than one switch may be turned on at a time to create the feature list you desire. The diagrams below are important to enable the MYGIG module to work with MYGIG radio systems.
#Lockpick air dip switch settings pro
Low Gas Heat Rise (Airflow) Adjustment S3-13, On your MYGIG LOCKPICK PRO control box are switch settings which allow you to program your Lockpick for your vehicle and the features you would like to enable. We set the temps down near 60f at times, then up to 68 ish, and we are in NO hurry for it to get there. It would mean the furnace only turns on if the room temp goes down 7 degrees, but never if UP 7.Īnd if I prefer the low speed to be set at 12, what do I set the high speed at in order to balance? If it has anything to do with how many degrees the stages run for, then neg 7 makes no sense. Default settings when shipped are 1, 2, down, 3, 4 and 5 up. From the instructions below, can anyone tell me what the numbers mean? +7f, -7f, 12f. your Lockpick for the vehicle and application where it will be installed. I have a non communicating Thermostat(Honeywell T5 smart stat), so I have to adjust from the dips. GREAT FOR LEASED CARS - UNPLUG IT AND YOUR CAR IS BACK TO STOCK. HUGE LIST OF STANDARD FEATURES ON THE NEW LOCKPICK AIR. (My installer crew didnt even take off the protection covers to the dips, and he is not returning my calls anymore). VIEW NEW UCONNECT LOCKPICK AIR V1 INSTRUCTIONS HERE.
#Lockpick air dip switch settings serial
Setting the DIP switch (RS-232C Serial Interface) 2. So I wanted to try adjusting the dip switches. Dip Switch Setting is different from each interface type. It turns on and off pretty often, which usually means its sized too large. I think everyone agrees that setting the cfm lower than 400/ton will give you better humidity removal, some are saying set it that way all the time and I was saying use this additional control to only do it when needed. I have a sparkly clean new furnace with variable speed motor, but it doesnt seem to run on low speed often enough. The actual cfm it moves is determined by the cfm settings(in this case for a 4 ton system) determined by the dip switch settings.
